Lab Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment
Lab temperature chamber Door opening alarm Temperature Humidity Chamber can simulate different environment condition. It's appropriate for testing material performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of material.
1. Specifications of Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment:
Range – 70 to 150°C
GAGGAGGAG
Temp/Humidity | GAG-E702-100-7 | GAG-E702-150-7 | GAG-E702-225-7 |
| GAG-E702-408-7 | GAG-E702-800-7 | GAG-E702-1000-7 |
Temp-only | GAG-E702-100-7 | GAG-E702-150T-7 | GAG-E702-225T-7 |
| GAG-E702-408T-7 | GAG-E702-800T-7 | GAG-E702-1000T-7 |
Temperature Range: | -70°C ~150°C |
Cooling Capacity | ~ 2.5 kW at -50°C | ~ 3 kW at -50°C | ~ 5 kW at -50°C |
| ~ 6.5 kW at-50°C | ~ 8.5 kW at -50°C | ~ 9 kW at - -50°C |
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW |
| ~6.5 kW | ~ 8.5 kW | ~ 9 kW |
Temperature Fluctuation: | ±0.5°C |
Temperature Gradient: | ±0.5°C~±0.2°C |
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) |
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) |
Humidity Fluctuation: | ±1.5%RH~±2.0%RH |
Humidity Gradient: | ±3%RH |
Dimensions |
Workspace dimensions (WxDxH)mm: | 500x400x500 GAG-E702-100 | 600x500x500 GAG-E702-150 | 750x500x600 GAG-E702-225 |
| 850x650x800 GAG-E702-800 | 1000x1000x800 GAG-E702-800 | 1000x1000x1000 GAG-E702-1000 |
Exterior dimensions (WxDxH)mm: | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 |
Site Requirements |
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
Humidity Water | Distilled water |
Condensate Drain: | 1/2" hose connection (gravity drain) |
Range – 40 to 150°C
Temp/Humidity | GAG-E702-100-4 | GAG-E702-150-4 | GAG-E702-225-4 |
| GAG-E702-408-4 | GAG-E702-800-4 | GAG-E702-1000-4 |
Temp-only | GAG-E702-100T-4 | GAG-E702-150T-4 | GAG-E702-225T-4 |
| GAG-E702-408T-4 | GAG-E702-800T-4 | GAG-E702-1000T-4 |
Temperature Range: | -40°C ~150°C |
Cooling Capacity | ~ 2 kW at -20°C | ~ 2.5 kW at -20°C | ~ 4.5 kW at -20°C |
| ~ 5.5 kW at-20°C | ~ 8 kW at -20°C | ~ 8.5 kW at - -20°C |
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW |
| ~6.5 kW | ~ 8.5 kW | ~ 9 kW |
Temperature Fluctuation: | ±0.5°C |
Temperature Gradient: | ±0.5°C~±0.2°C |
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) |
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) |
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) |
Humidity Fluctuation: | ±1.5%RH~±2.0%RH |
Humidity Gradient: | ±3%RH |
Dimensions |
Workspace dimensions (WxDxH)mm: | 500x400x500 GAG-E702-100 | 600x500x500 GAG-E702-150 | 750x500x600 GAG-E702-225 |
| 850x650x800 GAG-E702-800 | 1000x1000x800 GAG-E702-800 | 1000x1000x1000 GAG-E702-1000 |
Exterior dimensions (WxDxH)mm: | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 |
Site Requirements |
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) |
Humidity Water | Distilled Water |
Condensate Drain: | 1/2" hose connection (gravity drain) |
2. Performance
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Gaoge can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
System & Performance Options
Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
Water-cooling system.
Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
Additional shelves, 50 Kg loading
Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters
3. Features of Stainless Steels Constant Temperature Humidity Chamber Climate Test Equipment:
Vice lock type door and foam silicone packing to ensure a perfect seal Cartridge type tank for easy adding and changing of water
Tempered glass window with lamps provides a clear view of samples in the chamber, beneficial during testing Easy cleaning of condenser air-filter to prevent deterioration of refrigeration system
Leakage breaker for power supply Over current protection Overheat / overcool protection Switch-off after alarm for over heating Water empty / Door open alarm Vice lock door type locking mechanism
Standard Features:
Stainless# 304 steel for interior
Paint steel for exterior
Foam-insulated door for rigidity and long life
Plastic water tank easy for maintenance
Observation Window with frost free function
High performance refrigeration system
Easy user interface for TEMI-880 PLC controller
One 100mm cable port/ Customer specified
One shelve, 10 Kg loading & 4 casters included
Van Type Sirocco,L134,Fan
PID controlled-Stainless Steel Humidifier
DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
USB port for data output
Anti-explosive interior lamps
Data logging chart recorders, paperless recorders stored data in the PLC.